AUTOMATIONWORXUser ManualHardware and Software of Lean Managed SwitchesUM EN FL SWITCH LMOrder No.: 2888851
FL SWITCH LM 1-2PHOENIX CONTACT 7278_en_01Features and Fields of Application of the LMS– Increased network performance by filtering data traffic:- Loc
FL SWITCH LM4-16PHOENIX CONTACT 7278_en_01Switch-Over Time Response to Be Expected for Spanning TreeOverview of the switch-over time response to be ex
Multicast Filtering7278_en_01 PHOENIX CONTACT 5-15 Multicast Filtering5.1 BasicsMulticast Multicast applications - other than Unicast applications us
FL SWITCH LM5-2PHOENIX CONTACT 7278_en_01detected by layer-2 switches. The switch enters the MAC addresses of the multicast receivers, which were obta
Multicast Filtering7278_en_01 PHOENIX CONTACT 5-3IGMP QueryAn LMS with activated query function actively transmits queries at intervals and evaluates
FL SWITCH LM5-4PHOENIX CONTACT 7278_en_01
Technical Data7278_en_01 PHOENIX CONTACT 6-16 Technical DataGeneral DataFunction Lean Managed Ethernet/Fast Ethernet Switch; conforms to standard IEEE
FL SWITCH LM6-2PHOENIX CONTACT 7278_en_01Minimum transmission length, including 3 dB system reserve, when using single-mode36 km glass fiber with F-G
Ordering Data7278_en_01 PHOENIX CONTACT 6-3Ordering DataPHOENIX CONTACT GmbH & Co. KGFlachsmarktstr. 832825 BlombergGermany+49 - 52 35 - 30 0+49 -
FL SWITCH LM6-4PHOENIX CONTACT 7278_en_01
Lean Managed Switch7278_en_01 PHOENIX CONTACT 1-3– Alarm contact/functional earth groundThe floating alarm contact and the optional functional earth g
FL SWITCH LM 1-4PHOENIX CONTACT 7278_en_011.1.3 Status and Diagnostic Indicators1.1.4 Firmware Versions and Their FunctionsFor the following switch ve
Lean Managed Switch7278_en_01 PHOENIX CONTACT 1-51.2 Assembly/Removal1.2.1 Assembly and Removal of the LMS Mount the LMS on a clean DIN rail according
FL SWITCH LM 1-6PHOENIX CONTACT 7278_en_011.2.3 Removal1. Remove all connectors.2. Pull down the positive latches using a suitable tool (e.g., screwdr
Lean Managed Switch7278_en_01 PHOENIX CONTACT 1-7Figure 1-6 LMS supply 1.3.2 Alarm ContactThe switch has a floating alarm contact. Under normal condit
FL SWITCH LM 1-8PHOENIX CONTACT 7278_en_011.3.3 V.24 (RS-232) Interface for External ManagementThe 6-pos. Mini-DIN female connector provides a serial
Startup and Functions7278_en_01 PHOENIX CONTACT 2-12 Startup and Functions2.1 Basic Settings2.1.1 Default Upon Delivery/Default SettingsBy default upo
FL SWITCH LM2-2PHOENIX CONTACT 7278_en_012.1.2.1 Valid IP ParametersIP parameters comprise the following three elements: "IP address", "
Startup and Functions7278_en_01 PHOENIX CONTACT 2-3IP addresses can be represented in decimal or hexadecimal form. In decimal notation, bytes are sepa
FL SWITCH LM2-4PHOENIX CONTACT 7278_en_012.1.2.3 Special IP Addresses for Special ApplicationsCertain IP addresses are reserved for special functions.
Startup and Functions7278_en_01 PHOENIX CONTACT 2-5ApplicationIf the ANDing of the address bits gives the local network address and the local subnetwo
FL SWITCH LM2-6PHOENIX CONTACT 7278_en_012.1.3 Flowchart After a Restart2.1.3.1 Loading the Configuration DataFigure 2-3 Flowchart: Loading the config
Startup and Functions7278_en_01 PHOENIX CONTACT 2-72.1.3.2 Assigning IP ParametersFigure 2-4 Flowchart: Assigning IP parametersStartup72780013Assignme
FL SWITCH LM2-8PHOENIX CONTACT 7278_en_012.2 Frame SwitchingThe managed switch operates in store-and-forward mode. When receiving a data packet, the s
Startup and Functions7278_en_01 PHOENIX CONTACT 2-9Flowchart for "Learning Addresses" Using the Example of Unicast AddressesFigure 2-5 Flowc
FL SWITCH LM2-10PHOENIX CONTACT 7278_en_012.2.4.1 VLAN/Prioritization TagThe LMS processes incoming data packets with regard to prioritization informa
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-13 Configuration and DiagnosticsLean Managed Switches offer several user interfaces for acce
FL SWITCH LM3-2PHOENIX CONTACT 7278_en_01Figure 3-1 Messages from the LMS in the Factory ManagerRight-click on one of the LMS messages and select the
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-3Once you have clicked on "Add", the device is added to the project and is indicat
Designation:Revision:Order No.:This user manual is valid for:05/2007AUTOMATIONWORX7278_en_01 PHOENIX CONTACTHardware and Software of Lean Managed Swit
FL SWITCH LM3-4PHOENIX CONTACT 7278_en_01SystemFigure 3-4 "System" menuIn this menu, you can add additional information in the white fields,
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-5Information about the device status and redundancy is displayed here. All the messages for
FL SWITCH LM3-6PHOENIX CONTACT 7278_en_01FirmwareFigure 3-7 "Firmware" menuHere you can view all information about the current device softwa
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-7UpdateFigure 3-8 "Update" menu3.2 Web-Based Management (WBM)3.2.1 General Functio
FL SWITCH LM3-8PHOENIX CONTACT 7278_en_013.2.2 Requirements for the Use of WBMAs the web server operates using the Hyper Text Transfer Protocol, a sta
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-93.2.2.2 Password ConceptAfter having entered the valid password, no further entry of the pa
FL SWITCH LM3-10PHOENIX CONTACT 7278_en_013.2.3.1 General InstructionsFigure 3-9 "Information" web pageContains a brief description of WBM a
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-11"Local Diagnostics" MenuThis page describes the meaning of the diagnostic and st
FL SWITCH LM3-12PHOENIX CONTACT 7278_en_013.2.3.3 General Configuration"IP Configuration" MenuThis page displays the set IP parameters and a
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-13Trap configuration This part of the table is used to view or modify the IP addresses of th
FL SWITCH LMPHOENIX CONTACT 7278_en_01Please Observe the Following NotesIn order to ensure the safe use of the product described, we recommend that yo
FL SWITCH LM3-14PHOENIX CONTACT 7278_en_01• Enter the device password (default: „private“) and click with the mouse on „Apply“.Figure 3-17 Web interfa
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-15"Change Password" MenuThis option can be used to specify the current password an
FL SWITCH LM3-16PHOENIX CONTACT 7278_en_01"General Configuration/Configuration Management" MenuThis table is used to view all parameters tha
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-17Load the last storedconfigurationThis option can be used to reload the last configuration
FL SWITCH LM3-18PHOENIX CONTACT 7278_en_013.2.4.1 Switch Station Reboot To trigger a reboot via the web interface, enter a valid password. Save the co
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-19Figure 3-25 "Port Configuration Table" web pagePort Configuration Individual con
FL SWITCH LM3-20PHOENIX CONTACT 7278_en_01"Ports/Port Statistics" Menu (only FL SWITCH LM ...)This menu provides detailed statistical inform
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-21"Ports/Port Mirroring" MenuActivation/deactivation and setting of port mirroring
FL SWITCH LM3-22PHOENIX CONTACT 7278_en_01"Diagnostics/Alarm Contact" MenuHere, you can set whether and for which events the alarm contact c
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-233.2.4.2 Rapid Spanning Tree / Multicast FilteringFor information about (Rapid) Spanning Tr
FL SWITCH LM7278_en_01 PHOENIX CONTACTGeneral Terms and Conditions of Use for Technical DocumentationPhoenix Contact GmbH & Co. KG reserves the ri
FL SWITCH LM3-24PHOENIX CONTACT 7278_en_013.3 Simple Network Management Protocol (SNMP)3.3.1 General FunctionSNMP is a manufacturer-independent standa
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-25Reading SNMP objects is not password-protected. However, a password is required for read a
FL SWITCH LM3-26PHOENIX CONTACT 7278_en_013.3.2 Diagram of SNMP ManagementFigure 3-32 Diagram of SNMPFL IL 24 BK-BOrd.-No.: 283300010/100LINKRCV100FAI
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-273.3.2.1 Tree Structure of the MIBFigure 3-33 Tree structure of the MIBNot all devices supp
FL SWITCH LM3-28PHOENIX CONTACT 7278_en_013.3.3 RFC1213-MIB - MIB II3.3.3.1 System Group (1.3.6.1.2.1.1)The system group has mandatory characters for
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-29sysContact sysName sysLocation sysServices sysORLastChange OID 1.3.6.1.2.1.1.4.0Syntax Oct
FL SWITCH LM3-30PHOENIX CONTACT 7278_en_013.3.3.2 Interface Group (1.3.6.1.2.1.2)The interface group contains information about device interfaces.3.3.
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-313.3.4.2 dot1dStp (1.3.6.1.2.1.17.2)3.3.4.3 dot1dSr (1.3.6.1.2.1.17.3)3.3.4.4 dot1dTp (1.3.
FL SWITCH LM3-32PHOENIX CONTACT 7278_en_013.3.4.5 dot1Static (1.3.6.1.2.1.17.5)-- (2) dot1dTpPortMaxInfo-- (3) dot1dTpPortInFrames-- (4) dot1dTpPortOu
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-333.3.5 Private MIBsThe private MIBs for the LMS from Phoenix Contact can be found under obj
FL SWITCH LMPHOENIX CONTACT 7278_en_01Statement of Legal AuthorityThis manual, including all illustrations contained herein, is copyright protected. U
FL SWITCH LM3-34PHOENIX CONTACT 7278_en_01Access ReadDescription Contains the manufacturer's name: Phoenix Contact GmbH & Co. KG.pxcBasicDesc
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-35Description Contains a brief description of the product group:Ethernet Installation System
FL SWITCH LM3-36PHOENIX CONTACT 7278_en_01flWorkDeviceOID 1.3.6.1.4.1.4346.11.11flWorkBasicOID 1.3.6.1.4.1.4346.11.11.1flWorkBasicName flWorkBasicDesc
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-37flWorkBasicSerialNumber flWorkBasicHWRevision flWorkBasicPowerStat flWorkBasicCompMaxCapac
FL SWITCH LM3-38PHOENIX CONTACT 7278_en_01flWorkNetIfParamPhyAddressflWorkNetIfParamIPAddressflWorkNetIfParamSubnetmaskflWorkNetIfParamGWIpAddressOID
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-39flWorkNetIfParamStatusflWorkNetIfParamSaveflWorkNetIfParamAssignmentflWorkNetPortOID 1.3.6
FL SWITCH LM3-40PHOENIX CONTACT 7278_en_01flWorkNetPortCapacityflWorkNetPortTableOID 1.3.6.1.4.1.4346.11.11.4.2.2flWorkNetPortEntry OID 1.3.6.1.4.1.43
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-41Description Contains the duplex mode of the selected port:Automatic 1Manual 2flWorkNetPort
FL SWITCH LM3-42PHOENIX CONTACT 7278_en_01flWorkFirmwareOID 1.3.6.1.4.1.4346.11.11.11flWorkFWInfoOID 1.3.6.1.4.1.4346.11.11.11.1Access ReadDescription
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-43flWorkFWInfoVersionflWorkFWInfoStateflWorkFWInfoDateflWorkFWInfoTimeflWorkFWInfoCopyrightO
Table of Contents7278_en_01 PHOENIX CONTACT iTable of Contents1 Lean Managed Switch ...
FL SWITCH LM3-44PHOENIX CONTACT 7278_en_01flWorkFWInfoBootVersionflWorkFWInfoBootStateflWorkFWInfoBootDateflWorkFWInfoBootTimeflWorkFWCtrlOID 1.3.6.1.
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-45flWorkFWCtrlResetflWorkFWCtrlHttpflWorkFWCtrlSNMPflWorkFWCtrlTrapDest1.3.6.1.4.1.4346.11.1
FL SWITCH LM3-46PHOENIX CONTACT 7278_en_01flWorkFWCtrlTrapDestCapacityMaxflWorkFWCtrlTrapDestEnableflWorkFWCtrlPasswdOID 1.3.6.1.4.1.4346.11.11.11.2.3
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-47flWorkFWCtrlPasswdSuccessflWorkFWCtrlLoginExpireflWorkFWCtrlUpdateOID 1.3.6.1.4.1.4346.11.
FL SWITCH LM3-48PHOENIX CONTACT 7278_en_01flWorkFWCtrlUpdateStatusflWorkFWCtrlUpdateExecuteflWorkFWCtrlRunningUpdateflWorkFWCtrlAutoUpdateflWorkFWCtrl
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-49OID 1.3.6.1.4.1.4346.11.11.11.2.5flWorkFWCtrlConfStatusflWorkFWCtrlConfSaveflWorkFWCtrlDef
FL SWITCH LM3-50PHOENIX CONTACT 7278_en_01flWorkFWCtrlSerialDataBitsflWorkFWCtrlSerialStopBitsflWorkFWCtrlSerialParityflWorkFWCtrlSerialFlowControlflS
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-51flSwitchCtrlSpanTree flSwitchCtrlRedundancy flSwitchCtrlMacTableErase flSwitchIgmpTableEra
FL SWITCH LM3-52PHOENIX CONTACT 7278_en_013.4 Management via Local V.24 (RS-232) Communication Interface3.4.1 General FunctionA local communication co
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-533.4.2 User Interface Functions3.4.2.1 Functions During the Boot Process After a RestartIf
FL SWITCH LMii PHOENIX CONTACT 7278_en_013.4 Management via Local V.24 (RS-232) Communication Interface ...
FL SWITCH LM3-54PHOENIX CONTACT 7278_en_01The login screen indicates the version of the firmware used. A password must be entered to make other settin
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-55Resetting to Default SettingsFigure 3-38 Resetting to default settingsThis screen can be u
FL SWITCH LM3-56PHOENIX CONTACT 7278_en_013.4.3 Starting With Faulty SoftwareIf the software installed on the LMS (firmware) is faulty, you can restor
Configuration and Diagnostics7278_en_01 PHOENIX CONTACT 3-57Press "a" to download the new software. The following message appears:Figure 3-4
FL SWITCH LM3-58PHOENIX CONTACT 7278_en_01Clicking "Send" starts the file transfer. The following screen shows the progress of the file tran
Rapid Spanning Tree7278_en_01 PHOENIX CONTACT 4-14 Rapid Spanning Tree 4.1 General Function4.1.1 General FunctionLoops The Rapid/Spanning Tree Protoco
FL SWITCH LM4-2PHOENIX CONTACT 7278_en_014.2 RSTP StartupStartup consists of two parts that must be executed in the specified order:1 Enable RSTP on a
Rapid Spanning Tree7278_en_01 PHOENIX CONTACT 4-3Now switch to the "RSTP General" menu. Here, you will find various information about the Sp
FL SWITCH LM4-4PHOENIX CONTACT 7278_en_01Figure 4-4 "RSTP Configuration" web pageMaximum Age of STP InformationSTP information (BPDU) is sen
Rapid Spanning Tree7278_en_01 PHOENIX CONTACT 4-5Oper Edge PortAll ports that do not receive any RSTP BPDUs become edge ports, i.e., ports that switch
Lean Managed Switch7278_en_01 PHOENIX CONTACT 1-11 Lean Managed Switch1.1 PropertiesThe Lean Managed Switch (LMS) is an Ethernet switch, which is suit
FL SWITCH LM4-6PHOENIX CONTACT 7278_en_01Figure 4-6 "RSTP Port Configuration" web pagePort NumberIndicates the number of the port currently
Rapid Spanning Tree7278_en_01 PHOENIX CONTACT 4-7Forward TransitionsIndicates how often the port switches from the "Discarding" state to the
FL SWITCH LM4-8PHOENIX CONTACT 7278_en_014.2.1.4 Enabling via Serial Interface Establish a connection to the switch as described in "Management v
Rapid Spanning Tree7278_en_01 PHOENIX CONTACT 4-9– Rule 1: Spanning Tree transparency for all infrastructure componentsAll infrastructure components u
FL SWITCH LM4-10PHOENIX CONTACT 7278_en_014.2.1.6 Example Topologies4.2.1.7 Redundant Coupling of Network SegmentsIn this example, two network segment
Rapid Spanning Tree7278_en_01 PHOENIX CONTACT 4-114.2.1.8 Flowchart for Specifying the Root PathFigure 4-10 Flowchart for specifying the root path4.2.
FL SWITCH LM4-12PHOENIX CONTACT 7278_en_01Figure 4-11 Specifying the root switch prioritySpecifying the Root Port and Designated PortThe root port and
Rapid Spanning Tree7278_en_01 PHOENIX CONTACT 4-134.2.1.10 Disabling the Spanning Tree Protocol/Using the Fast Forwarding Function4.2.1.11 Modifying t
FL SWITCH LM4-14PHOENIX CONTACT 7278_en_01Figure 4-12 Example 1 for the "relevant path"72780011Inactive connectionRelevant path forsetting t
Rapid Spanning Tree7278_en_01 PHOENIX CONTACT 4-15Figure 4-13 Example 2 for the "relevant path"4.2.1.12 Reconfiguration TimesThe reconfigura
Kommentare zu diesen Handbüchern